Diagnostics (Basel) ; 12(6)2022 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-35741143

RESUMO

The traveled distance and orientation of capsule endoscopes for each video frame are not available in commercial systems, but they would be highly relevant for physicians. Furthermore, scientific approaches lack precisely tracking the capsules along curved trajectories within the typical gastrointestinal tract. Recently, we showed that the differential static magnetic localisation method is suitable for the precise absolute localisation of permanent magnets assumed to be integrated into capsule endoscopes. Thus, in the present study, the differential method was employed to track permanent magnets in terms of traveled distance and orientation along a length trajectory of 487.5 mm, representing a model of the winding gastrointestinal tract. Permanent magnets with a diameter of 10 mm and different lengths were used to find a lower boundary for magnet size. Results reveal that the mean relative distance and orientation errors did not exceed 4.3 ± 3.3%, and 2 ± 0.6∘, respectively, when the magnet length was at least 5 mm. Thus, a 5 mm long magnet would be a good compromise between achievable tracking accuracy and magnet volume, which are essential for integration into small commercial capsules. Overall, the proposed tracking accuracy was better than that of the state of the art within a region covering the typical gastrointestinal-tract size.

2.
Sensors (Basel) ; 22(2)2022 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35062385

RESUMO

Diabetes is a chronic and, according to the state of the art, an incurable disease. Therefore, to treat diabetes, regular blood glucose monitoring is crucial since it is mandatory to mitigate the risk and incidence of hyperglycemia and hypoglycemia. Nowadays, it is common to use blood glucose meters or continuous glucose monitoring via stinging the skin, which is classified as invasive monitoring. In recent decades, non-invasive monitoring has been regarded as a dominant research field. In this paper, electrochemical and electromagnetic non-invasive blood glucose monitoring approaches will be discussed. Thereby, scientific sensor systems are compared to commercial devices by validating the sensor principle and investigating their performance utilizing the Clarke error grid. Additionally, the opportunities to enhance the overall accuracy and stability of non-invasive glucose sensing and even predict blood glucose development to avoid hyperglycemia and hypoglycemia using post-processing and sensor fusion are presented. Overall, the scientific approaches show a comparable accuracy in the Clarke error grid to that of the commercial ones. However, they are in different stages of development and, therefore, need improvement regarding parameter optimization, temperature dependency, or testing with blood under real conditions. Moreover, the size of scientific sensing solutions must be further reduced for a wearable monitoring system.


Assuntos
Diabetes Mellitus , Hipoglicemia , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus/diagnóstico , Humanos , Hipoglicemia/diagnóstico , Monitorização Fisiológica , Reprodutibilidade dos Testes
3.
Sensors (Basel) ; 21(9)2021 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-34063644

RESUMO

Capsule endoscopy is a well-established diagnostic tool for the gastrointestinal tract. However, the reliable tracking of capsule endoscopes needs further investigation. Recently, the static magnetic differential method for the localization of capsule endoscopes has shown promising results. This method was experimentally validated by investigating the difference in the measured values of the geomagnetic flux density of a representative sensor pair. In the measurements, it was revealed that misalignment of the sensors and ferromagnetic material near the sensor pair had the most significant impact on the differential approach. Besides, a systematical simulation-based study was conducted. Herein, the position and alignment of all sensors of the localization system were randomly varied. Furthermore, root-mean-squared noise was added to the sensor measurements, and the influence of nearby ferromagnetic material was evaluated. Subsequently, non-idealities were applied simultaneously on the proposed localization system, and the entire system was rotated. The proposed method was significantly better than state-of-the-art geomagnetic compensation methods for the localization of capsule endoscopes with mean position and orientation errors of approximately 2 mm and 1°, respectively.


Assuntos
Cápsulas Endoscópicas , Endoscopia por Cápsula , Trato Gastrointestinal , Magnetismo
4.
Sensors (Basel) ; 20(4)2020 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-32054136

RESUMO

This paper proposes a robust and real-time capable algorithm for classification of the firstand second heart sounds. The classification algorithm is based on the evaluation of the envelope curveof the phonocardiogram. For the evaluation, in contrast to other studies, measurements on twelveprobands were conducted in different physiological conditions. Moreover, for each measurement theauscultation point, posture and physical stress were varied. The proposed envelope-based algorithmis tested with two different methods for envelope curve extraction: the Hilbert transform andthe short-time Fourier transform. The performance of the classification of the first heart soundsis evaluated by using a reference electrocardiogram. Overall, by using the Hilbert transform,the algorithm has a better performance regarding the F1-score and computational effort. Theproposed algorithm achieves for the S1 classification an F1-score up to 95.7% and in average 90.5 %.The algorithm is robust against the age, BMI, posture, heart rate and auscultation point (exceptmeasurements on the back) of the subjects. The ECG and PCG records are available from the authors.


Assuntos
Algoritmos , Eletrocardiografia/métodos , Ruídos Cardíacos/fisiologia , Fonocardiografia/métodos , Adulto , Idoso , Análise de Fourier , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador , Adulto Jovem